OBSOLETE SEE TEK284

OBSOLETE SEE TEK284

Item #: TEK263
Supplier #: 263

The Boiler Control 263 is designed to stage multiple boilers or operate a modulating boiler using Outdoor Temperature Reset. It can be used in applications ranging from a single zone of baseboard, multiple baseboard and fan coil zones, to dedicated Domestic Hot Water heating in commercial buildings. This control regulates a single heating water temperature through Outdoor Temperature Reset, setpoint, and DHW target control. It is capable of controlling (stage and rotate) up to 2 on/off boilers, a single 2 stage boiler, or 1 modulating boiler as well as the system pump.

For Further Information and up to date literature visit: Tekmar Documentation

Avail in Various Locations
UOM : EA
PUMP SEQUENCER STAND-BY/ 2 STG

PUMP SEQUENCER STAND-BY/ 2 STG

Item #: TEK132
Supplier #: 132

The Pump Sequencer 132 is designed to operate 2 pumps by providing stand-by or staging operation. It can be used in a wide range of applications, including residential installations using a backup system pump to commercial applications that require energizing a second stage for increased flow or head. The main function of the 132 is to provide lead lag capability to a standby pump setup, or to provide staging capability for a dual pump installation. The 132 can energize up to 2 pumps, as well as provide alert contacts that can be used in the event of a failure.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
BOILER CNTRL 1 tN4 4 STG BOILER AND DH

BOILER CNTRL 1 tN4 4 STG BOILER AND DH

Item #: TEK274
Supplier #: 274

The Boiler Control 274 is designed to stage multiple boilers using Outdoor Temperature Reset. It can be used in applications ranging from a single zone of baseboard, multiple baseboard and fan coil zones, to dedicated domestic hot water heating in commercial buildings. This control regulates a single heating water temperature through Outdoor Temperature Reset and/or setpoint/DHW target control. It is capable of controlling (stage and rotate) up to 4 on/off boilers as well as the system pump.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
OBSOLETE SEE TEK284

OBSOLETE SEE TEK284

Item #: TEK265
Supplier #: 265

The Boiler Control 265 is designed to stage multiple modulating boilers using Outdoor Temperature Reset. It can be used in applications ranging from baseboard or radiant heating systems, to dedicated domestic hot water heating in commercial buildings. This control regulates a single heating water temperature through Outdoor Temperature Reset and/or setpoint/DHW control. It is capable of controlling (stage and rotate) up to 3 modulating boilers by using a native 4-20 mA (or 0-20 mA) signal that can be converted to 2-10 V (dc) or 0-10 V (dc), as well as the system pump.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
BOILER CNTRL-9 STAGE AND DHW/SETPOINT

BOILER CNTRL-9 STAGE AND DHW/SETPOINT

Item #: TEK268
Supplier #: 268

The Boiler Control 268 is designed to stage multiple boilers using Outdoor Temperature Reset. It can be used in applications ranging from baseboard or mixed radiant heating systems, to dedicated domestic hot water heating in commercial buildings. This control regulates a single heating water temperature through Outdoor Temperature Reset and/or Setpoint/DHW target control. It is capable of controlling (stage and rotate) up to 9 on/off boilers as well as the system pump.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
BOILER CNTRL 1 tN4 MODULATING BLR DHW

BOILER CNTRL 1 tN4 MODULATING BLR DHW

Item #: TEK275
Supplier #: 275

The Boiler Control 275 is designed to stage up to four condensing or non-condensing, modulating or on-off boilers using P.I.D. staging to accurately maintain temperature. Water temperature is controlled by Outdoor Temperature Reset for space heating applications or a fixed setpoint for Domestic Hot Water (DHW) tank heating or industrial process heating applications. The control will also accept an analog 0-10 V (dc) signal from an Energy Management System (EMS) to control the water temperature. Boiler Equal Run Time Rotation, pump exercising and stand-by system pump operation increase boiler plant reliability. The control is tekmarNet® communication compatible allowing for internet connectivity using an optional Gateway 483.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
BOILER CONTROL 4 Tn4 BAS

BOILER CONTROL 4 Tn4 BAS

Item #: TEK284
Supplier #: 284

The Boiler Control 284 is designed to operate up to four boilers to accurately maintain a target water temperature. The 284 operates both condensing & non-condensing boilers that are either modulating, single stage or two stage to provide a flexible, cost effective mixed boiler plant solution with better system performance. The target water temperature is based on outdoor temperature reset or a fixed setpoint for space or process heating applications. Additional loads supplied by the 284 include domestic hot water & fixed setpoint heating. Boiler equal run-time rotation, stand-by primary pump operation & pump exercising all increase boiler plant reliability. The 284 communicates with a Building Automation System (BAS) using BACnet® or Modbus® for remote monitoring & adjustment capability. tekmarNet® Thermostats or a tN4 Gateway 485 can be added to optimize system performance & provide remote monitoring capability.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA