tekmarNet 4 TIMER

tekmarNet 4 TIMER

Item #: TEK033
Supplier #: 033

The tekmarNet® 4 Timer 033 provides a programmable setback schedule for an entire tekmarNet® system. It maintains time and communicates up to 4 schedules on the network that up to 96 tekmarNet® thermostats can follow. This product can also be used in stand alone applications.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
INDOOR SENSOR COVER PLATE

INDOOR SENSOR COVER PLATE

Item #: TEK077
Supplier #: 077

The Indoor Sensor 077 is designed to act as a remote indoor temperature sensor. It can be used in a number of applications for indoor temperature sensing, and is sized for attachment to a 2” x 4” electrical box. This is a 10K thermistor designed to be installed with a compatible tekmar thermostat or control.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
THREE OUTDOOR SENSOR MODULE

THREE OUTDOOR SENSOR MODULE

Item #: TEK081
Supplier #: 081

The Three Outdoor Sensor Module 081 includes three 10 k? thermistors which provides an accurate measurement of the outdoor temperature. Each sensor has two separate terminals for wiring. The 081 is designed to be installed in a tekmar Outdoor Sensor 070 enclosure. This allows for four separate sensors to be combined into a single enclosure that is mounted on the exterior of the building.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
DUCT SENSOR 6 PROBE

DUCT SENSOR 6 PROBE

Item #: TEK083
Supplier #: 083

The Duct Sensor 083 is a 10 k? temperature sensor designed to measure the average temperature of the air stream in a heating, cooling, or ventilation duct. It has a 6” (150 mm) long probe connected to a 2” x 4” electrical box for easy wiring.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
INDOOR SENSOR FLUSH MOUNT

INDOOR SENSOR FLUSH MOUNT

Item #: TEK084
Supplier #: 084

The Indoor Sensor 084 mounts flush or nearly flush to the wall to give an unobtrusive look and act as a hidden indoor sensor. Since the sensor material is corrosion resistant, drywall installers are able to mud over the sensor, or the 084 can be painted to match the existing wall color. The 084 can be connected to a tekmar thermostat for remote temperature sensing.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
SOLAR SENSOR 5' (1.5M) WIRE

SOLAR SENSOR 5' (1.5M) WIRE

Item #: TEK085
Supplier #: 085

The Solar Sensor 085 is designed to be used as a sensor in solar applications. It has a stainless steel head and silicone jacketed wire, ideal for use as an immersion well sensor in a solar collector. This sensor is commonly used to measure the source temperature at a solar thermal collector.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
HUMIDITY TEMP SENSOR FLUSH MOUNT

HUMIDITY TEMP SENSOR FLUSH MOUNT

Item #: TEK086
Supplier #: 086

The Humidity & Temperature Sensor 086 can be connected to select tekmar thermostats to remotely measure relative humidity and temperature. The 086 mounts flush or nearly flush to the wall to allow the sensor to visually blend in with the surrounding wall.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
tN4 USER SWITCH 3 INPUTS

tN4 USER SWITCH 3 INPUTS

Item #: TEK480
Supplier #: 480

The tekmarNet® 4 User Switch 480 is a simple 3 button switch that provides an easy way to override system temperatures. With the push of a button, one can put all thermostats and boiler controls into an “unoccupied” or “away” state and take advantage of saving energy when the building is not being used. The buttons on this product are also programmable, allowing the user to experience scenes within their system. The 480 has three demand inputs that can provide access to tekmarNet® 4 scenes or setpoint devices from a telephone switch, home automation, or security systems.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
tN4 USER SWITCH 3 OUTPUTS

tN4 USER SWITCH 3 OUTPUTS

Item #: TEK481
Supplier #: 481

The tekmarNet® 4 User Switch 481 is a simple 3 button switch that provides an easy way to override system temperatures. With the push of a button one can put all thermostats and boiler controls into an “unoccupied” or “away” state and take advantage of saving energy when the building is not being used. The buttons on this product are also programmable, allowing the user to experience scenes within their system. The 481 has three output relays that can connect to alarm, paging, or home automation systems.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
3-WAY MIXING VALVE 1 BRASS

3-WAY MIXING VALVE 1 BRASS

Item #: TEK711
Supplier #: 711

The 3-Way Brass Mixing Valve 711 is used to mix supply water from a hydronic source with water returning from a system. It is designed for use in either closed loop or open loop hydronic systems. This 3-way valve has standard female NPT threads, as well as a maximum leak through rate of 1% to allow for water expansion during temperature changes. The valve position can be manually set using the handle. An Actuating Motor 741 can be used to automatically operate the valve.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability