Browse Categories

Search Filters

  • Tekmar Controls x

Browse Categories

Loading...

Search Results

tN2 HOUSE CONTROL BOILER 4 ZONE VALVES

tN2 HOUSE CONTROL BOILER 4 ZONE VALVES

Item #: TEK400
Supplier #: 400

The tekmarNet® 2 House Control 400 is designed to operate all of the mechanical equipment in a residential hydronic heating system, coordinating their operation with network communication. It can be used in applications ranging from a single zone of baseboard with an on/off boiler, to multiple radiant floor zones with a modulating/condensing boiler. This control regulates one space heating water temperature through Outdoor Temperature Reset and Indoor Temperature Feedback. It is capable of controlling a single on/off, two stage, or modulating boiler, Domestic Hot Water, setpoint loads, 4 on-board zone valves, and can expand up to 24 zones in total.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
tN2 HOUSE CONTROL BOILER 4 ZONE PUMPS

tN2 HOUSE CONTROL BOILER 4 ZONE PUMPS

Item #: TEK401
Supplier #: 401

The tekmarNet® 2 House Control 401 is designed to operate all of the mechanical equipment in a residential hydronic heating system, coordinating their operation through network communication. It can be used in applications ranging from a single zone of baseboard with an on/off boiler, to multiple radiant floor zones with a modulating/condensing boiler. This control regulates one space heating water temperature through Outdoor Temperature Reset and Indoor Temperature Feedback. It is capable of controlling a single on/off, two stage, or modulating boiler, Domestic Hot Water, setpoint loads, 4 on-board zone pumps, and can expand up to 24 zones in total.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
tN2 HOUSE CNTRL BOILER MXNG 4 ZONE VLV

tN2 HOUSE CNTRL BOILER MXNG 4 ZONE VLV

Item #: TEK402
Supplier #: 402

The tekmarNet® 2 House Control 402 is designed to operate all the mechanical equipment in a residential hydronic heating system, coordinating their operation through network communication. It can be used in applications ranging from a single zone of baseboard with an on/off boiler to multiple fan coils, mixed radiant floor heating zones, and a modulating/condensing boiler. This control regulates up to two heating water temperatures through Outdoor Temperature Reset and Indoor Temperature Feedback. It is capable of controlling a single on/off, two stage, or modulating boiler, a mixing device, Domestic Hot Water, setpoint loads, 4 on-board zone valves, and can expand up to 24 zones in total for each space heating water temperature.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
tN2 HOUSE CNTRL BOILER MXNG 4 ZONE PUM

tN2 HOUSE CNTRL BOILER MXNG 4 ZONE PUM

Item #: TEK403
Supplier #: 403

The tekmarNet® 2 House Control 403 is designed to operate all of the mechanical equipment in a residential hydronic heating system, coordinating their operation through network communication. It can be used in applications ranging from a single zone of baseboard with an on/off boiler, to multiple fan coils, mixed radiant floor heating zones, and a modulating/condensing boiler. This control regulates up to two heating water temperatures through Outdoor Temperature Reset and Indoor Temperature Feedback. It is capable of controlling a single on/off, two stage, or modulating boiler, a mixing device, Domestic Hot Water, setpoint loads, 4 on-board zone pumps, and can expand up to 24 zones in total for each space heating water temperature.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
tN2 HOUSE CONTROL HEAT PUMP

tN2 HOUSE CONTROL HEAT PUMP

Item #: TEK406
Supplier #: 406

The tekmarNet®2 House Control 406 is designed to operate the equipment in a 2-pipe, single tank, hydronic heating and cooling system. It operates two heat pump stages (water-to-water or air-to-water) with a backup heat source (boiler or electric resistance). The heat pump provides either hot or chilled water to a storage tank loop and optional mixed temperature loop. For radiant heating, the water temperature is calculated using Outdoor Temperature Reset. For radiant cooling, the chilled water temperature is maintained at an adjustable setpoint, or is adjusted using dew-point reset with a humidity sensor. A backup boiler can provide an Outdoor Temperature Reset water temperature as well as domestic hot water and setpoint water temperatures. The 406 operates 4 on-board heating and cooling zones and is expandable up to 52 zones on the boiler, tank, and mix water temperatures.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
UNI RESET MODULE 2 tN4 MIXING BOIL

UNI RESET MODULE 2 tN4 MIXING BOIL

Item #: TEK422
Supplier #: 422

The Universal Reset Module 422 is designed to operate all of the mechanical equipment in a hydronic heating system, except for zones, coordinating their operation through network communication. It can be used in applications ranging from a single zone of baseboard with an on/off boiler to multiple fan coils, mixed radiant floor zones, and a modulating/condensing boiler. This control regulates up to two heating water temperatures through Outdoor Temperature Reset and Indoor Temperature Feedback. It is capable of controlling a single on/off, two stage, or modulating boiler, a mixing device, Domestic Hot Water, setpoint loads, and can expand up to 24 zones in total for each heating water temperature.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
UNIVERSAL RESET MODULE 4 tN4 2 BOILER

UNIVERSAL RESET MODULE 4 tN4 2 BOILER

Item #: TEK423
Supplier #: 423

The Universal Reset Module 423 is designed to operate all of the mechanical equipment in a hydronic heating system, except for zones, coordinating their operation through network communication. It can be used in applications ranging from a single zone of baseboard with an on/off boiler, to four temperature systems comprised of multiple fan coils, baseboard, mixed radiant floor zones, and two modulating/condensing boilers. This control regulates up to four space heating water temperatures through Outdoor Temperature Reset and Indoor Temperature Feedback. It is capable of controlling two on/off or modulating boilers, Domestic Hot Water, setpoint loads, and can expand up to 24 zones for each space heating water temperature (96 in total).

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
MIXING EXPANSION MODULE VARIABLE SPEED

MIXING EXPANSION MODULE VARIABLE SPEED

Item #: TEK440
Supplier #: 440

The Mixing Expansion Module 440 is designed to operate a mixing device within a hydronic heating system as part of a tekmarNet® control system. It is capable of controlling a mixed system pump and a 24 V floating action mixing valve or a wet rotor circulator for variable speed injection.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
MIXING EXPANSION MODULE ACTUATING MTR

MIXING EXPANSION MODULE ACTUATING MTR

Item #: TEK441
Supplier #: 441

The Mixing Expansion Module 441 is designed to operate any of the tekmar 3-way and 4-way brass mixing valves from type 710 through type 724. It provides 6 N•m (53 in•lbs) of torque over a 90° rotation. This product is controlled through digital communication on tekmarNet® systems.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
MIXING EXPANSION MODULE VARIABLE SPEED

MIXING EXPANSION MODULE VARIABLE SPEED

Item #: TEK444
Supplier #: 444

The Mixing Expansion Module 444 is designed to operate a mixing device within a hydronic heating system as part of a tekmarNet® control system. It is capable of controlling a mixed system pump and six optional outputs for mixing: a variable speed injection pump, a floating action actuator, or an analog 0-10 V (dc), 2-10 V (dc), 0-20 mA, or 4-20 mA signal.

For Further Information and up to date literature visit: Tekmar Documentation

Call 513-251-4343 for Availability
UOM : EA
  • « PREV
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • NEXT »